Examples

Running a scenario

How an instructor moves a case along from the Remote: what to say, what learners should do, and when to stage and apply each change so the Display stays believable. These show how to use the tool; they are not clinical guidance.

Say
What you tell learners out loud.
Learners
What you expect the team to do.
Remote
What you stage and apply, and when.

Adult opioid overdose: ventilation and naloxone

Adult · Basic mode · about 15 minutes

A 55-year-old is found barely breathing after an opioid overdose, needs ventilation, wakes with naloxone and later becomes drowsy again as the naloxone wears off. It stays in Basic mode, where a new session starts: gradual changes, the apnea rule, and automatic NIBP cycling.

  1. Before learners arrive

    Remote
    1. Create a session and open the Display on the learners’ screen (see Getting started). A new session starts in Basic mode with an adult patient, which is all this case needs.
    2. Stage the starting patient:
      • HR 64
      • SpO₂ 86
      • RR 6
      • NIBP 104/62
      • Temperature 36.2
      Set Timing to Now and press Apply now.
    3. On Monitor settings, set Automatic cycling to Every 5 min and press Apply settings. The cuff then cycles by itself, so you only press Cycle NIBP when the team asks for a pressure sooner.
  2. Recognize respiratory depression

    Say
    “This 55-year-old man was found unresponsive in the bathroom by his partner. He’s making snoring sounds. His pupils are pinpoint.” If they check: “Glucose is normal.”
    Learners
    Open the airway, assess breathing, call for help, ventilate with a bag and mask on oxygen, and get naloxone ready.
    Remote

    If nobody supports his breathing within a minute or so, let him stop breathing:

    • RR 0
    • SpO₂ 78
    • HR 54

    Press Apply over 30 s. Breathing slows to nothing, and at RR 0 the respiration trace goes flat. Values never drive each other, so the falling heart rate is there only because you staged it.

    Once bag-mask ventilation is going well, stage the bagging rate and a recovering saturation:

    • RR 10
    • SpO₂ 95
    • HR 72

    Press Apply over 30 s. If the seal is poor or the airway is not open, hold off until the team fixes it.

  3. Naloxone

    Say
    “Naloxone is in.” About a minute later: “He opens his eyes and pulls at the mask. He’s agitated and says he feels sick.”
    Learners
    Keep ventilating until he breathes well on his own, then reassess, give oxygen by mask, reassure him, and watch for vomiting and withdrawal.
    Remote

    Stage this while the dose goes in, and apply as he wakes:

    • RR 18
    • SpO₂ 97
    • HR 104
    • NIBP 148/88

    Press Apply over 30 s. The cuff reading does not change until its next cycle; press Cycle NIBP if the team asks for a pressure now.

  4. The naloxone wears off

    Say
    “Five minutes later he’s drowsy again and hard to rouse. His partner finds a pack of long-acting tablets.”
    Learners
    Recognize renarcotization, support breathing again, repeat naloxone and consider an infusion, and plan a longer period of monitoring.
    Remote
    • RR 8
    • SpO₂ 89
    • HR 68
    • NIBP 112/70

    Press Apply over 60 s for a slow decline. When the repeat dose is in, stage RR 16, SpO₂ 96 and HR 90 and press Apply over 30 s to end the case.

Child with septic shock: PEA arrest and ROSC

Child · Advanced mode · about 20 minutes

A 4-year-old in septic shock worsens despite fluids, arrests with an organized rhythm and no pulse, and has a return of spontaneous circulation after CPR, epinephrine and more fluid. It uses gradual changes for trends, immediate changes for events, the NIBP cuff on request, the arrest and CPR controls, and the Simulation log to rewind for a second attempt.

  1. Before learners arrive

    Remote
    1. Open the Display on the learners’ screen (see Getting started). Learners will watch it fill in as you set up, so do this before they come in or cover the screen.
    2. Open Simulation options and turn Advanced mode on. It takes effect at once and adds the rhythm, circulation, Arterial line and EtCO₂ controls this case needs.
    3. Choose Child. This starts a new child patient: normal child vitals and the default devices, as pending changes. Edit over them to stage the starting patient:
      • HR 150
      • SpO₂ 92
      • RR 36
      • NIBP 82/40
      • Temperature 39.4
      Then, under SpO₂ / Pleth, open Advanced and set Dampening to 40 for a small, rounded pleth.
    4. Leave Arterial line and End-tidal CO₂ off. They come on later, when the team places them.
    5. Set Timing to Now and press Apply now. A new age clears the NIBP reading, so the Display shows no cuff pressure until someone asks for one.
  2. Recognize shock

    Say
    “This is a 4-year-old with two days of fever and vomiting, now hard to wake. Her hands are cool and mottled, and capillary refill is 5 seconds. She hasn’t urinated since last night.”
    Learners
    Assess airway, breathing and circulation, give oxygen, ask for a blood pressure, get IV or IO access, and give a fluid bolus. Sending cultures and giving antibiotics early is a bonus.
    Remote

    When the team asks for a blood pressure, press Cycle NIBP. It acts at once: the Display shows the cuff cycling and the reading appears about 20 seconds later, just as a real cuff makes them wait.

    When oxygen goes on, stage a slow rise:

    • SpO₂ 97

    Set Timing to 30 s and press Apply over 30 s. The saturation climbs over half a minute instead of jumping, and the Remote shows its progress under the field.

  3. Partial response to fluid

    Say
    “The first bolus is in.” If they reassess: “Capillary refill is 4 seconds.”
    Learners
    Reassess after the bolus, recognize ongoing shock, and give a second bolus while watching for signs of fluid overload.
    Remote

    Stage this while the team is still talking, so it is ready the moment the bolus finishes. Nothing reaches the Display until you apply.

    • HR 138
    • NIBP 90/50
    • Dampening 25

    Choose 60 s and press Apply over 60 s: the heart rate eases down over a minute, as it would after fluid.

    The cuff reading on the Display does not change when you apply new BP values. The Remote marks it as outdated, which is your note, not the learners’. Press Cycle NIBP when the team asks for a repeat pressure.

  4. Fluid-refractory shock

    Say
    “After the second bolus she is harder to rouse and working hard to breathe.”
    Learners
    Recognize shock that is not responding to fluid, start an epinephrine infusion, call for help, and plan an arterial line and intubation.
    Remote

    Worsen the patient in one gradual change:

    • HR 168
    • RR 44
    • SpO₂ 90
    • NIBP 70/34
    • Dampening 60

    Press Apply over 60 s. Each vital moves on its own clock, so a later Apply that changes only one of them leaves the others gliding.

    When the team places an arterial line, turn the Arterial line switch on and set it to 68/32. With Keep BP correlated on (the default), NIBP now follows the Arterial line and is read-only; change pressures in the Arterial line from here on. Apply now so the trace appears as the line is connected.

    If the team intubates here, you could stage and apply vital changes the same way, turning on End-tidal CO₂ once the tube is in.

  5. PEA arrest

    Say
    “The nurse says she isn’t responding anymore.” Then let the monitor speak.
    Learners
    Notice the organized rhythm with no pleth and a flat arterial trace, check for a pulse, call for help and start compressions.
    Remote
    1. Under HR / Rhythm, keep Sinus rhythm and set HR to 50.
    2. Open Advanced under HR / Rhythm and set Patient has a pulse? to No. The Remote shows No pulse at the top and stages the arrest presets: RR 0, EtCO₂ 0 and Arterial line 0/0. The Display: … lines under SpO₂, NIBP and Arterial line tell you what learners will see.
    3. Set Timing to Now and press Apply now, so the slow rate and the lost pulse land together. The ECG keeps drawing sinus rhythm at 50 while the pleth, pulse tone and arterial trace go flat.
  6. CPR and rhythm checks

    Say
    Answer what they ask for. “Epinephrine is in.” If they look for reversible causes: “Glucose is 52.”
    Learners
    High-quality compressions, epinephrine every 3–5 minutes, rhythm checks every 2 minutes, and a search for reversible causes: more fluid for hypovolemia, glucose, ventilation.
    Remote

    The moment compressions start, press Start CPR. It acts at once, without Apply: compression artifact covers the ECG, HR shows —, and the arterial trace rises with each compression. Arrest zeros fill with child CPR values: Arterial line 65/30, RR 25 and EtCO₂ 15.

    Coach compression quality with the numbers learners watch. If compressions are shallow or the team tires, stage

    • Arterial line 40/15
    • EtCO₂ 8

    and Apply now. When they swap compressors or push harder, put them back up. If the team compresses noticeably faster or slower, set Compression rate to match so the artifact looks like what they are doing.

    At each rhythm check, press Pause CPR. The artifact stops and the ECG shows sinus rhythm at 50 again, still with no pleth: PEA. When compressions resume, press Start CPR again; values you set are kept.

  7. Return of spontaneous circulation

    Say
    At the pulse check after the second epinephrine dose and more fluid: “You feel a pulse.”
    Learners
    Confirm the pulse, stop compressions, then support blood pressure and oxygenation, ask for a pressure, and prepare to move her to intensive care.
    Remote
    1. During the last cycle of CPR, stage the return: HR 140, and Patient has a pulse? to Yes. The Remote stages the pre-arrest RR, EtCO₂ and Arterial line values for any that still hold an arrest or CPR default; values you set during CPR stay.
    2. Check those staged values and edit them for after the arrest:
      • Arterial line 76/40
      • RR 24
      • EtCO₂ 38
      • SpO₂ 94
    3. At the pulse check, press Pause CPR and then Apply now. A returning pulse shows at once: pleth, pulse tone and the arterial waveform come back together. An Apply that restores the pulse also stops CPR, in case it is still running.
    4. Press Cycle NIBP when they ask for a pressure. Then, as the team titrates epinephrine, stage HR 128, Arterial line 92/50 and Dampening 20, and choose Apply over 60 s for a slow, steady improvement to end on.
  8. Optional: rewind and run the arrest again

    Say
    “Let’s pause there.” Debrief the arrest briefly: how long until compressions started, who led, what was missed. “We’ll go back to just before she arrested and run it again.”
    Learners
    Run the arrest again with the debrief in mind: recognize it sooner, start compressions within seconds, and keep roles clear.
    Remote
    1. Open Simulation log at the bottom of Patient settings. Every Apply added an entry, with its changes marked. Find the last entry before the arrest, the one that turned the Arterial line on: Arterial line ON at 68/32.
    2. Press Stage on it. Its vitals and devices, pulse included, become pending changes, with nothing to retype and no arrest presets. Nothing reaches the Display until you apply.
    3. Set Timing to Now and press Apply now. Learners see the fluid-refractory patient again; the cuff keeps its last reading until someone cycles it. Run PEA arrest from there.
    4. For the debrief, Copy as text gives a timed record of both attempts.

The rules behind each change, such as arrest presets, CPR values and NIBP cycling, are in the Documentation.